V-L 180-300/10-1G

Dimensions:
External H x W x D (mm)
2300 x 1400 x 1400
Usable space
Volume (l) 7.6
Ø x H (mm) 180 x 300
Thermal values
Tmax vacuum (°C) 1050
ΔT (K) according to DIN 17052 ± 3 *
Cooling time (min) 30
Thermocouple type K
Connecting values
Power (kW) 12
Voltage (V) 400 (3P)
Current (A) 3 x 30
Series fuse (A) 3 x 35
Controller
Manual operation Eurotherm with KP 300 panel
Automatic operation Siemens
Cooling water required
Flow (l/min) 30

Please note:
* at a height of 300 mm with a three zone furnace