Search

Controlled Atmosphere Oven - HTMA

Controlled Atmosphere Oven - HTMA
HTMA 6/28

HTMA 4/28

Max temp (°C) 400
Volume (litres) 28

[read more] [read less]

Heat-up time (mins) 60
Recovery time (mins) 10
Dimensions:
Internal H x W x D (mm)
305 x 305 x 305
Dimensions:
External H x W x D (mm)
990 x 810 x 885
Shelves fitted / accepted 2 / 2
Shelf loading each / total (kg) 10 / 20
Max power (W) 1000
Weight (kg) 73

HTMA 4/95

Max temp (°C) 400
Volume (litres) 95

[read more] [read less]

Heat-up time (mins) 75
Recovery time (mins) 16
Dimensions:
Internal H x W x D (mm)
455 x 455 x 455
Dimensions:
External H x W x D (mm)
1120 x 1015 x 1120
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 15 / 30
Max power (W) 3000
Weight (kg) 99

HTMA 4/220

Max temp (°C) 400
Volume (litres) 220

[read more] [read less]

Heat-up time (mins) 120
Recovery time (mins) 20
Dimensions:
Internal H x W x D (mm)
610 x 610 x 610
Dimensions:
External H x W x D (mm)
1270 x 1165 x 1280
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 25 / 30
Max power (W) 4000
Weight (kg) 179

HTMA 4/500

Max temp (°C) 400
Volume (litres) 500

[read more] [read less]

Heat-up time (mins) ---
Recovery time (mins) ---
Dimensions:
Internal H x W x D (mm)
800 x 800 x 800
Dimensions:
External H x W x D (mm)
1305 x 1115 x 1450
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) -- / --
Max power (W) 7500
Weight (kg) ---

HTMA 4/1000

Max temp (°C) 400
Volume (litres) 1000

[read more] [read less]

Heat-up time (mins) ---
Recovery time (mins) ---
Dimensions:
Internal H x W x D (mm)
1000 x 1000 x 1000
Dimensions:
External H x W x D (mm)
1310 x 1530 x 1635
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) -- / --
Max power (W) 12000
Weight (kg) ---

HTMA 5/28

Max temp (°C) 500
Volume (litres) 28

[read more] [read less]

Heat-up time (mins) 60
Recovery time (mins) 10
Dimensions:
Internal H x W x D (mm)
305 x 305 x 305
Dimensions:
External H x W x D (mm)
990 x 810 x 885
Shelves fitted / accepted 2 / 2
Shelf loading each / total (kg) 10 / 20
Max power (W) 2000
Weight (kg) 73

HTMA 5/95

Max temp (°C) 500
Volume (litres) 95

[read more] [read less]

Heat-up time (mins) 75
Recovery time (mins) 16
Dimensions:
Internal H x W x D (mm)
455 x 455 x 455
Dimensions:
External H x W x D (mm)
1120 x 1015 x 1120
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 15 / 30
Max power (W) 4500
Weight (kg) 99

HTMA 5/220

Max temp (°C) 500
Volume (litres) 220

[read more] [read less]

Heat-up time (mins) 120
Recovery time (mins) 20
Dimensions:
Internal H x W x D (mm)
610 x 610 x 610
Dimensions:
External H x W x D (mm)
1270 x 1165 x 1280
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 25 / 50
Max power (W) 6000
Weight (kg) 179

HTMA 5/500

Max temp (°C) 500
Volume (litres) 500

[read more] [read less]

Heat-up time (mins) ---
Recovery time (mins) ---
Dimensions:
Internal H x W x D (mm)
800 x 800 x 800
Dimensions:
External H x W x D (mm)
1305 x 1115 x 1450
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) -- / --
Max power (W) 9000
Weight (kg) ---

HTMA 5/1000

Max temp (°C) 500
Volume (litres) 1000

[read more] [read less]

Heat-up time (mins) ---
Recovery time (mins) ---
Dimensions:
Internal H x W x D (mm)
1000 x 1000 x 1000
Dimensions:
External H x W x D (mm)
1310 x 1530 x 1635
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) -- / --
Max power (W) 15000
Weight (kg) ---

HTMA 6/28

Max temp (°C) 600
Volume (litres) 28

[read more] [read less]

Heat-up time (mins) 60*
Recovery time (mins) 10*
Dimensions:
Internal H x W x D (mm)
305 x 305 x 305
Dimensions:
External H x W x D (mm)
990 x 810 x 885
Shelves fitted / accepted 2 / 2
Shelf loading each / total (kg) 10 / 20
Max power (W) 2000
Weight (kg) 73

HTMA 6/95

Max temp (°C) 600
Volume (litres) 95

[read more] [read less]

Heat-up time (mins) 75*
Recovery time (mins) 16*
Dimensions:
Internal H x W x D (mm)
455 x 455 x 455
Dimensions:
External H x W x D (mm)
1120 x 1015 x 1120
Shelves fitted / accepted 3 / 4
Shelf loading (each) / total (kg) 15 / 30
Max power (W) 4500
Weight (kg) 99

HTMA 6/220

Max temp (°C) 600
Volume (litres) 220

[read more] [read less]

Heat-up time (mins) 120*
Recovery time (mins) 20*
Dimensions:
Internal H x W x D (mm)
610 x 610 x 610
Dimensions:
External H x W x D (mm)
1270 x 1165 x 1280
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 25 / 50
Max power (W) 6000
Weight (kg) 179

HTMA 6/500

Max temp (°C) 600
Volume (litres) 500

[read more] [read less]

Heat-up time (mins) ---
Recovery time (mins) ---
Dimensions:
Internal H x W x D (mm)
800 x 800 x 800
Dimensions:
External H x W x D (mm)
1305 x 1115 x 1450
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) -- / --
Max power (W) 12000
Weight (kg) ---

HTMA 6/1000

Max temp (°C) 600
Volume (litres) 1000

[read more] [read less]

Heat-up time (mins) ---
Recovery time (mins) ---
Dimensions:
Internal H x W x D (mm)
1000 x 1000 x 1000
Dimensions:
External H x W x D (mm)
1310 x 1530 x 1635
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) -- / --
Max power (W) 15000
Weight (kg) ---

HTMA 7/28

Max temp (°C) 700
Volume (litres) 28

[read more] [read less]

Heat-up time (mins) 90
Recovery time (mins) 24
Dimensions:
Internal H x W x D (mm)
305 x 305 x 305
Dimensions:
External H x W x D (mm)
1140 x 910 x 910
Shelves fitted / accepted 2 / 2
Shelf loading each / total (kg) 8 / 16
Max power (W) 3000
Weight (kg) 85

HTMA 7/95

Max temp (°C) 700
Volume (litres) 95

[read more] [read less]

Heat-up time (mins) 95
Recovery time (mins) 24
Dimensions:
Internal H x W x D (mm)
455 x 455 x 455
Dimensions:
External H x W x D (mm)
1280 x 1110 x 1160
Shelves fitted / accepted 3 / 4
Shelf loading (each) / total (kg) 10 / 30
Max power (W) 6000
Weight (kg) 115

HTMA 7/220

Max temp (°C) 700
Volume (litres) 220

[read more] [read less]

Heat-up time (mins) 120
Recovery time (mins) 24
Dimensions:
Internal H x W x D (mm)
610 x 610 x 610
Dimensions:
External H x W x D (mm)
1295 x 1215 x 1280
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 15 / 45
Max power (W) 10000
Weight (kg) 195

Please note
- Uniformity is measured in an empty chamber with vents closed, after a stabilisation period
- * Nominal values based upon a representative sample of products
- Minimum operating temperature is approximately ambient +60°C
- Maximum power and heat up times based on a 240V supply

Content may be subject to modifications or corrections