Modular Vertical Tube Furnace - GVA / GVC

Close all | none













GVA 12/300

Max temp (°C) 1200
Number of heated zones Single zone
Dimensions: Heated tube length (mm) 300

[read more] [read less]

Heat-up time (mins) 90
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 480
Recommended tube length for use in air (mm) 500
Recommended tube length for use with modified atmosphere (mm) 900
Dimensions: External Furnace body (inc stand) H x W x D (mm) 1345 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Dimensions: Clearance under furnace (mm) 251 to 778
Uniform length ±5°C (mm) --
Max power (W) 2300
Thermocouple type N
Weight (kg) 73

GVA 12/450

Max temp (°C) 1200
Number of heated zones Single zone
Dimensions: Heated tube length (mm) 450

[read more] [read less]

Heat-up time (mins) 75
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 630
Recommended tube length for use in air (mm) 650
Recommended tube length for use with modified atmosphere (mm) 1050
Dimensions: External Furnace body (inc stand) H x W x D (mm) 1418 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Dimensions: Clearance under furnace (mm) 177 to 702
Uniform length ±5°C (mm) --
Max power (W) 3100
Thermocouple type N
Weight (kg) 87

GVA 12/600

Max temp (°C) 1200
Number of heated zones Single zone
Dimensions: Heated tube length (mm) 600

[read more] [read less]

Heat-up time (mins) 70
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 780
Recommended tube length for use in air (mm) 800
Recommended tube length for use with modified atmosphere (mm) 1200
Dimensions: External Furnace body (inc stand) H x W x D (mm) 1418 x 648 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Dimensions: Clearance under furnace (mm) 177 to 550
Uniform length ±5°C (mm) --
Max power (W) 3900
Thermocouple type N
Weight (kg) 95

GVA 12/750

Max temp (°C) 1200
Number of heated zones Single zone
Dimensions: Heated tube length (mm) 750

[read more] [read less]

Heat-up time (mins) 80
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 930
Recommended tube length for use in air (mm) 950
Recommended tube length for use with modified atmosphere (mm) 1350
Dimensions: External Furnace body (inc stand) H x W x D (mm) 1793 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Dimensions: Clearance under furnace (mm) 177 to 777
Uniform length ±5°C (mm) --
Max power (W) 4600
Thermocouple type N
Weight (kg) 100

GVA 12/900

Max temp (°C) 1200
Number of heated zones Single zone
Dimensions: Heated tube length (mm) 900

[read more] [read less]

Heat-up time (mins) --
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 1080
Recommended tube length for use in air (mm) 1100
Recommended tube length for use with modified atmosphere (mm) 1500
Dimensions: External Furnace body (inc stand) H x W x D (mm) 1860 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Dimensions: Clearance under furnace (mm) 100 to 702
Uniform length ±5°C (mm) --
Max power (W) 5400
Thermocouple type N
Weight (kg) 110

GVA 12/1050

Max temp (°C) 1200
Number of heated zones Single zone
Dimensions: Heated tube length (mm) 1050

[read more] [read less]

Heat-up time (mins) 67
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 1230
Recommended tube length for use in air (mm) 1250
Recommended tube length for use with modified atmosphere (mm) 1650
Dimensions: External Furnace body (inc stand) H x W x D (mm) 1943 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Dimensions: Clearance under furnace (mm) 26 to 627
Uniform length ±5°C (mm) --
Max power (W) 6200
Thermocouple type N
Weight (kg) 120

GVA 12/1200

Max temp (°C) 1200
Number of heated zones Single zone
Dimensions: Heated tube length (mm) 1200

[read more] [read less]

Heat-up time (mins) 83
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 1380
Recommended tube length for use in air (mm) 1400
Recommended tube length for use with modified atmosphere (mm) 1800
Dimensions: External Furnace body (inc stand) H x W x D (mm) 2018 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Dimensions: Clearance under furnace (mm) 26 to 551
Uniform length ±5°C (mm) 845
Max power (W) 7000
Thermocouple type N
Weight (kg) 130

GVC 12/450

Max temp (°C) 1200
Number of heated zones Three zone
Dimensions: Heated tube length (mm) 450

[read more] [read less]

Heat-up time (mins) 75
Max continuous operating temp (°C) 1100
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 630
Recommended tube length for use in air (mm) 650
Recommended tube length for use with modified atmosphere (mm) 1050
Dimensions: External Furnace H x W x D (mm) 1418 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Clearance under furnace H (mm) 177 to 702
Uniform length ±5°C (mm) 300
Max power (W) 3100
Holding power (W) 1500
Thermocouple type N
Weight (kg) 87

GVC 12/600

Max temp (°C) 1200
Number of heated zones Three zone
Dimensions: Heated tube length (mm) 600

[read more] [read less]

Heat-up time (mins) 80
Max continuous operating temp (°C) 1100
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 780
Recommended tube length for use in air (mm) 800
Recommended tube length for use with modified atmosphere (mm) 1200
Dimensions: External Furnace H x W x D (mm) 1418 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Clearance under furnace H (mm) 177 to 550
Uniform length ±5°C (mm) 440
Max power (W) 3900
Holding power (W) 1800
Thermocouple type N
Weight (kg) 95

GVC 12/750

Max temp (°C) 1200
Number of heated zones Three zone
Dimensions: Heated tube length (mm) 750

[read more] [read less]

Heat-up time (mins) 92
Max continuous operating temp (°C) 1100
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 930
Recommended tube length for use in air (mm) 950
Recommended tube length for use with modified atmosphere (mm) 1350
Dimensions: External Furnace H x W x D (mm) 1793 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Clearance under furnace H (mm) 177 to 777
Uniform length ±5°C (mm) 500
Max power (W) 4600
Holding power (W) 2200
Thermocouple type N
Weight (kg) 100

GVC 12/900

Max temp (°C) 1200
Number of heated zones Three zone
Dimensions: Heated tube length (mm) 900

[read more] [read less]

Heat-up time (mins) 111
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 1080
Recommended tube length for use in air (mm) 1100
Recommended tube length for use with modified atmosphere (mm) 1500
Dimensions: External Furnace H x W x D (mm) 1860 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Clearance under furnace H (mm) 100 to 702
Uniform length ±5°C (mm) 640
Max power (W) 5400
Holding power (W) 2281
Thermocouple type N
Weight (kg) 110

GVC 12/1050

Max temp (°C) 1200
Number of heated zones Three zone
Dimensions: Heated tube length (mm) 1050

[read more] [read less]

Heat-up time (mins) 122
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 1230
Recommended tube length for use in air (mm) 1250
Recommended tube length for use with modified atmosphere (mm) 1650
Dimensions: External Furnace H x W x D (mm) 1943 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Clearance under furnace H (mm) 26 to 627
Uniform length ±5°C (mm) 880
Max power (W) 6200
Holding power (W) 2800
Thermocouple type N
Weight (kg) 68

GVC 12/1200

Max temp (°C) 1200
Number of heated zones Three zone
Dimensions: Heated tube length (mm) 1200

[read more] [read less]

Heat-up time (mins) 82
Dimensions: Max outer diameter accessory tube (mm) 170
Dimensions: Furnace body length (mm) 1380
Recommended tube length for use in air (mm) 1500
Recommended tube length for use with modified atmosphere (mm) 1400
Dimensions: External Furnace H x W x D (mm) 2018 x 468 x 662
Dimensions: Control module H x W x D (mm) 225 x 600 x 380
Clearance under furnace H (mm) 26 to 551
Uniform length ±5°C (mm) 1015
Max power (W) 7000
Holding power (W) 3163
Thermocouple type N
Weight (kg) 130

Please note:
- Heat up rate when using a ceramic work tube must be limited to 5 °C/min
- Heat up rate is measured to 100°C below max, using an empty tube & insulation plugs
- Dimensions excluding control box (225 x 600 x 380 mm)
- Maximum continuous operating temperature is 100°C below maximum temperature
- Holding power is measured at continuous operating temperature
- Uniform length measured with insulation plugs fitted

Content may be subject to modifications or corrections