Bottom loading furnace, metal insulation - HTBL MO/W

Close all | none


HTBL 60 MO/16-1G

Insulation material Molybdenum
Volume (litres) 60
Tmax vacuum (°C) 1600

[read more] [read less]

Dimensions:
External H x W x D (mm)
3300 x 2400 x 2200
Transport weight (kg) 3400
Usable space
Ø x H, usable space without retort (mm) 400 x 500
Ø x H, usable space with retort (mm) 380 x 480
Thermal values
Tmax atmospheric pressure (°C) 1600
ΔT , between 500°C and 2200°C (K) according to DIN 17052 ± 10
Max. heat-up rate (K/min) 10
Cooling time (h) 5
Connecting values
Power (kW) 80
Voltage (V) 400 (3P)
Current (A) 3 x 115
Series fuse (A) 3 x 160
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit rough, fine, high or ultra high vacuum
Cooling water required
Flow (l/min) 64
Gas supply
Nitrogen or Argon flow, others on request (l/h) 500-2000
Controller Siemens

HTBL 60 W/16-1G

Insulation material Tungsten
Volume (litres) 60
Tmax vacuum (°C) 2200

[read more] [read less]

Dimensions:
External H x W x D (mm)
3300 x 2400 x 2200
Transport weight (kg) 3600
Usable space
Ø x H, usable space without retort (mm) 400 x 500
Ø x H, usable space with retort (mm) 380 x 480
Thermal values
Tmax atmospheric pressure (°C) 2200
ΔT , between 500°C and 2200°C (K) according to DIN 17052 ± 10
Max. heat-up rate (K/min) 10
Cooling time (h) 6
Connecting values
Power (kW) 250
Voltage (V) 400 (3P)
Current (A) 3 x 360
Series fuse (A) 3 x 500
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s) < 5x10-3
Vacuum range depending on the pumping unit rough, fine, high or ultra high vacuum
Cooling water required
Flow (l/min) 200
Gas supply
Nitrogen or Argon flow, others on request (l/h) 500-2000
Controller Siemens

Content may be subject to modifications or corrections