Search

Top hat furnace - V-L

V-L 180-300/10-1G V-L 450-600/10-1G
Dimensions:
External H x W x D (mm)
2300 x 1400 x 1400 3200 (open) x 2300 x 2000
Usable space

Volume (l) 7.6 95
Ø x H (mm) 180 x 300 450 x 600
Thermal values

Tmax vacuum (°C) 1050 1050
-Delta-T (K) according to DIN 17052 ± 3 * ± 3 *
Cooling time (min) 30 30
Thermocouple type K K
Connecting values

Power (kW) 12 58
Voltage (V) 400 (3P) 400 (3P)
Current (A) 3 x 30 3 x 110
Series fuse (A) 3 x 35 3 x 150
Controller

Manual operation Eurotherm with KP 300 panel Eurotherm with KP 300 panel
Automatic operation Siemens Siemens
Cooling water required

Flow (l/min) 30 30

Please note
* at a height of 300 mm with a three zone furnace

Content may be subject to modifications or corrections